Altigen ACM 6.5 Uživatelská příručka Strana 466

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 502
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 465
452 MAXCS ACM 6.5 Administration Manual
Figure 1. Physical Layer
Consult your CO for “Frame Type,”Line Code,” orZero Code Suppression.”
Do not check the System Clock Master check box because the CO is a clock
provider, and the AltiGen system is synchronized to the CO. If all configurations are
correct, the status should be shown as “OK,” as in Figure 1.
3. Click the Protocol button in the Channel Group Configuration dialog box to open the
Protocol Configuration window.
Figure 2. Data Link Layer
4. Select E1 CAS as the Span Type, and select the Switch Mode according to your
country in the E1 R2 Setting field, and click OK.
5. In the Trunk Configuration window, click the Trunk Properties button to open the
E1 Channel Configuration window.
Zobrazit stránku 465
1 2 ... 461 462 463 464 465 466 467 468 469 470 471 ... 501 502

Komentáře k této Příručce

Žádné komentáře