Altigen MAXCS 7.0 Update 1 Upgrade Guidelines Uživatelský manuál Strana 4

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 6
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 3
AltiGen Communications, Inc. MAXCS 7.0 Update 1 Upgrade Guidelines Page 4 of 6
IP address is in the IP dialing table list
IP address is in the SIP Allow IP list
The caller is from another AltiGen system
The caller is from an AltiGen IP phone
The filter is disabled by default. To enable the filter, add the following registry entry and press VM&SP
Log Dump under the Diagnostics > Trace menu (or just restart the system).
HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\AltiGen Communications, Inc.\AltiWare\Service
Providers\SIPSP
"BlockSIPUnauthorizedCall"=dword:00000001
Software Upgrade Path
The diagram on the next page shows the software upgrade path (not license registration) to convert older MAXCS
databases to the 7.0 Update 1 version.
It is critical to follow the upgrade instructions to avoid losing configuration data.
Note: If you are upgrading from release 6.5 or earlier, you have two options:
You can rekey the data in Release 7.0 Update 1, or
You can upgrade to release 6.5 Update 1, and then upgrade from 6.5 Update 1 to Release 7.0 Update 1